posted on 2025-08-06, 15:04authored byC Suemi da Costa Rosa, L Gracia Marco, AR Barker, IF Freitas Junior, HL Monteiro
Aim: To compare the short version of International Physical Activity Questionnaire (IPAQ) and the accelerometer measurement of physical activity (PA) in patients undergoing hemodialysis. Methods: Sample consisted of 40 patients (19 men) aged 45 ± 16 years. Patients reported their PA using the IPAQ during a face-to-face interview, and wore an Actigraph GT3-X accelerometer for 1 week to obtain minutes per day of light PA, moderate-to-vigorous PA (MVPA) and total PA as well as raw counts per day (vector magnitude). Results: All PA-related variables were significantly correlated among instruments (r = 0.34-0.47) when analyzed as a group. However, when analyzed separately by gender, the relationships were present for women only (r = 0.46-0.62). IPAQ significantly underestimated light PA (IPAQ vs. accelerometer: 180.0 vs. 251.1 min/day, p = 0.019), but no differences were found between methods for MVPA and total PA. Conclusion: Modest correlations were found between self-reported PA time by IPAQ (short version) and accelerometer, but only in women. However, the IPAQ may underestimate light PA, which is the main form of PA in this population.
This is the peer-reviewed but unedited manuscript version of the following article: Blood Purification 2015;40:3, pp.250-255. The final, published version is available at http://www.karger.com/?doi=10.1159/000437040