University of Exeter
Browse

Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep

Download (569 kB)
journal contribution
posted on 2025-08-01, 14:53 authored by AMA Muhammad, N Ibrahim, R Ahmad, MK Asif, Z Radzi, ZM Zaini, HRA Razak
BACKGROUND: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment. METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15). RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%. CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value.

Funding

FRGS/1/2015/SKK14/UITM/02/2

Malaysia Higher Education Fundamental Research Grant Scheme

Ministry of Higher Education, Malaysia

UM.C/625/1/HIR/MOHE/DENT/21

Universiti Teknologi Mara (UiTM)

History

Related Materials

Rights

© The Author(s). 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Notes

This is the final version. Available on open access from BMC via the DOI in this record Availability of data and materials: The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request.

Journal

BMC Oral Health

Pagination

48-

Publisher

BMC

Place published

England

Version

  • Version of Record

Language

en

FCD date

2022-07-07T12:23:27Z

FOA date

2022-07-07T12:26:21Z

Citation

Vol. 20, article 48

Department

  • Archive

Usage metrics

    University of Exeter

    Categories

    No categories selected

    Licence

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC