University of Exeter
Browse

Exponential integrators for a Markov chain model of the fast sodium channel of cardiomyocytes

Download (450.04 kB)
journal contribution
posted on 2025-08-06, 14:16 authored by T. Stary, V. N. Biktashev
The modern Markov chain models of ionic channels in excitable membranes are numerically stiff. The popular numerical methods for these models require very small time steps to ensure stability. Our objective is to formulate and test two methods addressing this issue, so that the timestep can be chosen based on accuracy rather than stability. Both proposed methods extend Rush-Larsen technique, which was originally developed to Hogdkin-Huxley type gate models. One method, "matrix Rush-Larsen" (MRL) uses a matrix reformulation of the Rush-Larsen scheme, where the matrix exponentials are calculated using precomputed tables of eigenvalues and eigenvectors. The other, "hybrid operator splitting" (HOS) method exploits asymptotic properties of a particular Markov chain model, allowing explicit analytical expressions for the substeps. We test both methods on the Clancy and Rudy (2002) [Formula: see text] Markov chain model. With precomputed tables for functions of the transmembrane voltage, both methods are comparable to the forward Euler method in accuracy and computational cost, but allow longer time steps without numerical instability. We conclude that both methods are of practical interest. MRL requires more computations than HOS, but is formulated in general terms which can be readily extended to other Markov chain channel models, whereas the utility of HOS depends on the asymptotic properties of a particular model. The significance of the methods is that they allow a considerable speed-up of large-scale computations of cardiac excitation models by increasing the time step, while maintaining acceptable accuracy and preserving numerical stability.

Funding

EP/I029664/1

Engineering and Physical Sciences Research Council (EPSRC)

History

Related Materials

Notes

Copyright © 2015 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

Journal

IEEE Transactions on Biomedical Engineering

Publisher

Institute of Electrical and Electronics Engineers (IEEE)

Place published

United States

Language

en

Citation

Vol. 62 (4), pp. 1070 - 1076

Department

  • Mathematics and Statistics

Usage metrics

    University of Exeter

    Categories

    No categories selected

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC