dc.contributor.author | Saynor, ZL | |
dc.contributor.author | Barker, AR | |
dc.contributor.author | Oades, PJ | |
dc.contributor.author | Williams, CA | |
dc.date.accessioned | 2015-08-27T11:22:26Z | |
dc.date.issued | 2013-12 | |
dc.description.abstract | BACKGROUND: The reproducibility of cardiopulmonary exercise testing (CPET) has not been established in young cystic fibrosis (CF) patients using a valid protocol. METHODS: Thirteen 7-18 year olds completed three CPETs, separated by 48 h and 4-6 weeks. CPET involved a ramp-incremental cycling test with supramaximal verification. RESULTS: Maximal oxygen uptake was repeatedly determined with no learning effect and typical errors expressed as a coefficient of variation (TE(CV%)) of 9.3% (48 h) and 13.3% (4-6 weeks). The reproducibility of additional parameters of aerobic function [gas exchange threshold (TE(CV%): 11.2%, 16.8%); VO2 mean response time (TE(CV%): 37.8%, 89.4%); VO2 gain (TE(CV%): 17.4%, 24.5%)] and clinical utility [e.g. SaO2% (TE(CV%): 2.2%, 3.1%); ventilatory drive (V(E)/VCO2-slope) (TE(CV%): 7.8%, 17.7%)] was also established over the short- and the medium-term, respectively. CONCLUSION: These results establish limits of variability to determine meaningful changes over the short- and the medium-term for CPET outcomes in young CF patients. | en_GB |
dc.identifier.citation | Vol. 12, pp. 644 - 650 | en_GB |
dc.identifier.doi | 10.1016/j.jcf.2013.04.012 | |
dc.identifier.other | S1569-1993(13)00071-4 | |
dc.identifier.uri | http://hdl.handle.net/10871/18140 | |
dc.language.iso | en | en_GB |
dc.publisher | Elsevier | en_GB |
dc.relation.url | http://www.ncbi.nlm.nih.gov/pubmed/23726255 | en_GB |
dc.rights | © 2013. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ | en_GB |
dc.subject | Cardiorespiratory fitness | en_GB |
dc.subject | Cystic fibrosis | en_GB |
dc.subject | Exercise testing | en_GB |
dc.subject | Maximal oxygen uptake | en_GB |
dc.subject | Reproducibility | en_GB |
dc.subject | Adolescent | en_GB |
dc.subject | Child | en_GB |
dc.subject | Cystic Fibrosis | en_GB |
dc.subject | Exercise Test | en_GB |
dc.subject | Female | en_GB |
dc.subject | Humans | en_GB |
dc.subject | Male | en_GB |
dc.subject | Oxygen Consumption | en_GB |
dc.subject | Pulmonary Gas Exchange | en_GB |
dc.subject | Reproducibility of Results | en_GB |
dc.title | Reproducibility of maximal cardiopulmonary exercise testing for young cystic fibrosis patients. | en_GB |
dc.type | Article | en_GB |
dc.date.available | 2015-08-27T11:22:26Z | |
dc.identifier.issn | 1569-1993 | |
exeter.place-of-publication | Netherlands | |
dc.description | Author manuscript version of an article published in the Journal of Cystic Fibrosis. The definitive published version is available via http://dx.doi.org/10.1016/j.jcf.2013.04.012. | en_GB |
dc.identifier.eissn | 1873-5010 | |
dc.identifier.journal | Journal of Cystic Fibrosis | en_GB |
dc.identifier.pmid | 23726255 | |