Show simple item record

dc.contributor.authorMediouni, M
dc.contributor.authorSchlatterer, DR
dc.contributor.authorKhoury, A
dc.contributor.authorVon Bergen, T
dc.contributor.authorShetty, SH
dc.contributor.authorArora, M
dc.contributor.authorDhond, A
dc.contributor.authorVaughan, N
dc.contributor.authorVolosnikov, A
dc.date.accessioned2021-03-22T15:50:03Z
dc.date.issued2017-02-09
dc.description.abstractThe drilling bone may potentially cause excessive frictional heat, which can lead to local bone necrosis. This heat generation and local necrosis has been suggested to contribute to the resorption of bone around the placed screws, ending in loss of screw purchase in the bone and inadvertent loosening and/or the bone-implant construct. In vivo studies on this subject have inherent obstacles not the least of which is controlling the variables and real time bone temperature data acquisition. Theoretical models can be generated using computer software and the inclusion of known constants for the mechanical properties of metal and bone. These known Data points for the variables (drill bit and bone) enables finite element analysis of various bone drilling scenarios. An elastic–plastic three-dimensional (3D) acetabular bone mode was developed and finite element model analysis (FEA) was applied to various simulated drilling procedures. The FEA results clearly indicate that the depth of drilling and the drill speed both have a significant effect on the temperature during drilling procedures. The reduction of the feeding speed leads to a reduction in bone temperature. Our data suggests that reducing the feeding speed regardless of RPMs and pressure applied could be a simple useful and effective way to reduce drilling temperatures. This study is the first step in helping any surgeon who drills bone and places screws to better understand the ideal pressure to apply and drill speed to employ and advance rate to avoid osteonecrosis.en_GB
dc.identifier.citationVol. 35 (11), pp. 2386 - 2391en_GB
dc.identifier.doi10.1002/jor.23542
dc.identifier.urihttp://hdl.handle.net/10871/125204
dc.language.isoenen_GB
dc.publisherWiley / Orthopaedic Research Societyen_GB
dc.rights© 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.en_GB
dc.subjectdrillingen_GB
dc.subjectosteonecrosisen_GB
dc.subjectfinite element analysis (FEA)en_GB
dc.titleOptimal parameters to avoid thermal necrosis during bone drilling: A finite element analysisen_GB
dc.typeArticleen_GB
dc.date.available2021-03-22T15:50:03Z
dc.identifier.issn0736-0266
dc.descriptionThis is the author accepted manuscript. The final version is available from Wiley via the DOI in this recorden_GB
dc.identifier.journalJournal of Orthopaedic Researchen_GB
dc.rights.urihttp://www.rioxx.net/licenses/all-rights-reserveden_GB
dcterms.dateAccepted2017-01-23
rioxxterms.versionAMen_GB
rioxxterms.licenseref.startdate2017-02-09
rioxxterms.typeJournal Article/Reviewen_GB
refterms.dateFCD2021-03-22T15:47:57Z
refterms.versionFCDAM
refterms.dateFOA2021-03-22T15:50:08Z
refterms.panelAen_GB