Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep
dc.contributor.author | Muhammad, AMA | |
dc.contributor.author | Ibrahim, N | |
dc.contributor.author | Ahmad, R | |
dc.contributor.author | Asif, MK | |
dc.contributor.author | Radzi, Z | |
dc.contributor.author | Zaini, ZM | |
dc.contributor.author | Razak, HRA | |
dc.date.accessioned | 2022-07-07T12:26:08Z | |
dc.date.issued | 2020-02-10 | |
dc.date.updated | 2022-07-07T11:36:25Z | |
dc.description.abstract | BACKGROUND: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment. METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15). RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%. CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value. | en_GB |
dc.description.sponsorship | Universiti Teknologi Mara (UiTM) | en_GB |
dc.description.sponsorship | Malaysia Higher Education Fundamental Research Grant Scheme | en_GB |
dc.description.sponsorship | Ministry of Higher Education, Malaysia | en_GB |
dc.format.extent | 48- | |
dc.format.medium | Electronic | |
dc.identifier.citation | Vol. 20, article 48 | en_GB |
dc.identifier.doi | https://doi.org/10.1186/s12903-020-1035-7 | |
dc.identifier.grantnumber | FRGS/1/2015/SKK14/UITM/02/2 | en_GB |
dc.identifier.grantnumber | UM.C/625/1/HIR/MOHE/DENT/21 | en_GB |
dc.identifier.uri | http://hdl.handle.net/10871/130181 | |
dc.language.iso | en | en_GB |
dc.publisher | BMC | en_GB |
dc.relation.url | https://www.ncbi.nlm.nih.gov/pubmed/32041589 | en_GB |
dc.rights | © The Author(s). 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. | en_GB |
dc.subject | CBCT | en_GB |
dc.subject | Reconstruction parameters | en_GB |
dc.subject | Threshold value | en_GB |
dc.subject | Trabecular bone | en_GB |
dc.title | Effect of reconstruction parameters on cone beam CT trabecular bone microstructure quantification in sheep | en_GB |
dc.type | Article | en_GB |
dc.date.available | 2022-07-07T12:26:08Z | |
dc.identifier.issn | 1472-6831 | |
exeter.article-number | 48 | |
exeter.place-of-publication | England | |
dc.description | This is the final version. Available on open access from BMC via the DOI in this record | en_GB |
dc.description | Availability of data and materials: The datasets used and/or analysed during the current study are available from the corresponding author on reasonable request. | en_GB |
dc.identifier.eissn | 1472-6831 | |
dc.identifier.journal | BMC Oral Health | en_GB |
dc.relation.ispartof | BMC Oral Health, 20(1) | |
dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | en_GB |
dcterms.dateAccepted | 2020-02-04 | |
dc.rights.license | CC BY | |
rioxxterms.version | VoR | en_GB |
rioxxterms.licenseref.startdate | 2020-02-10 | |
rioxxterms.type | Journal Article/Review | en_GB |
refterms.dateFCD | 2022-07-07T12:23:27Z | |
refterms.versionFCD | VoR | |
refterms.dateFOA | 2022-07-07T12:26:21Z | |
refterms.panel | A | en_GB |
refterms.dateFirstOnline | 2020-02-10 |
Files in this item
This item appears in the following Collection(s)
Except where otherwise noted, this item's licence is described as © The Author(s). 2020 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.