Show simple item record

dc.contributor.authorKnapp, KM
dc.contributor.authorWelsman, JR
dc.contributor.authorHopkins, SJ
dc.contributor.authorShallcross, A
dc.contributor.authorFogelman, Ignac
dc.contributor.authorBlake, Glen M.
dc.date.accessioned2015-07-09T11:50:10Z
dc.date.issued2015-04-01
dc.description.abstractTotal body (TB) dual-energy X-ray absorptiometry (DXA) is increasingly being used to measure body composition in research and clinical settings. This study investigated the effect of body mass index (BMI) and body fat on precision errors for total and regional TB DXA measurements of bone mineral density, fat tissue, and lean tissue using the GE Lunar Prodigy (GE Healthcare, Bedford, UK). One hundred forty-four women with BMI's ranging from 18.5 to 45.9kg/m<sup>2</sup> were recruited. Participants had duplicate DXA scans of the TB with repositioning between examinations. Participants were divided into 3 groups based on their BMI, and the root mean square standard deviation and the percentage coefficient of variation were calculated for each group. The root mean square standard deviation (percentage coefficient of variation) for the normal (<25kg/m<sup>2</sup>; n=76), overweight (25-30kg/m<sup>2</sup>; n=36), and obese (>30kg/m<sup>2</sup>; n=32) BMI groups, respectively, were total BMD (g/cm<sup>2</sup>): 0.009 (0.77%), 0.009 (0.69%), 0.011 (0.91%); total fat (g): 545 (2.98%), 486 (1.72%), 677 (1.55%); total lean (g): 551 (1.42%), 540 (1.34%), and 781 (1.68%). These results suggest that serial measurements in obese subjects should be treated with caution because the least significant change may be larger than anticipated.en_GB
dc.identifier.citationJournal of Clinical Densitometry, 2015, Vol. 18 (2), pp. 209 - 216en_GB
dc.identifier.doi10.1016/j.jocd.2014.06.001
dc.identifier.urihttp://hdl.handle.net/10871/17845
dc.language.isoenen_GB
dc.publisherElsevier Inc.en_GB
dc.relation.urlhttp://www.ncbi.nlm.nih.gov/pubmed/25087044en_GB
dc.rights.embargoreasonPublisher's policyen_GB
dc.rights© 2015. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0en_GB
dc.subjectBone mineral densityen_GB
dc.subjectDual-energy X-ray absorptiometryen_GB
dc.subjectObesityen_GB
dc.subjectPrecisionen_GB
dc.titleObesity increases precision errors in total body dual-energy x-ray absorptiometry measurementsen_GB
dc.typeArticleen_GB
dc.identifier.issn1094-6950
dc.descriptionThis is the author’s version of a work that was accepted for publication in the Journal of Clinical Densitometry. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published at doi: 10.1016/j.jocd.2014.06.001.en_GB
dc.identifier.journalJournal of Clinical Densitometryen_GB


Files in this item

This item appears in the following Collection(s)

Show simple item record