dc.contributor.author | Liu, H | |
dc.contributor.author | Walski, T | |
dc.contributor.author | Fu, G | |
dc.contributor.author | Zhang, C | |
dc.date.accessioned | 2016-11-21T14:50:33Z | |
dc.date.issued | 2017-03-01 | |
dc.description.abstract | Isolation valves are crucial components of water distribution systems for separating pipe
segments from the network for repair or maintenance purpose. This paper looks at the impacts
of isolation valves failure on the three indictors including number of valves that are needed to
isolate a distribution system segment, the size of distribution system segments and the shortfall
in meeting demands during failure. A network with various isolation valve configurations in
terms of the density of valves is used as a case study. The results obtained from the case study
show that the failure of an isolation valve has substantially varying impacts on system
performance during a shutdown. The density of valves in the network determines impacts of
inoperable valves on a shutdown. Generally speaking, a higher density of isolation valves leads
to the less impact of valve failure. Finally, several conclusions drawn from the critical valve
analysis in this study could be applied to guide the isolation valve maintenance and
management. | en_GB |
dc.description.sponsorship | Bentley Systems provided the software to conduct the hydraulic simulation and valve
segmentation. This study is financially supported by the National Natural Science Foundation
of China (51320105010, 51579027), the National Science and Technology Major Project
(2014ZX03005001), and Ministry of Water Resource of China (Grant No.201401014-2), which
are greatly acknowledged. | en_GB |
dc.identifier.citation | Published online: March 01, 2017 | en_GB |
dc.identifier.doi | http://dx.doi.org/10.1061/(ASCE)WR.1943-5452.0000766 | |
dc.identifier.uri | http://hdl.handle.net/10871/24521 | |
dc.language.iso | en | en_GB |
dc.publisher | American Society of Civil Engineers | en_GB |
dc.subject | water distribution system | en_GB |
dc.subject | isolation valves | en_GB |
dc.subject | failure | en_GB |
dc.subject | criticality analysis | en_GB |
dc.title | Failure impact analysis of isolation valves in a water distribution | en_GB |
dc.type | Article | en_GB |
dc.identifier.issn | 0733-9496 | |
dc.description | This is the author accepted manuscript. The final version is available from American Society of Civil Engineers via the DOI in this record. | |
dc.identifier.journal | Journal of Water Resources Planning and Management | en_GB |