dc.description.abstractAtrial fibrillation (AF) affects ~3% of the general population and is twice as common with hypertension. Validation protocols for automated sphygmomanometers exclude people with AF, raising concerns over accuracy of hypertension diagnosis or management, using out-of-office blood pressure (BP) monitoring, in the presence of AF. Some devices include algorithms to detect AF; a feature open to misinterpretation as offering accurate BP measurement with AF. We undertook this review to explore accuracy of automated devices, with or without AF detection, for measuring BP. We searched Medline and Embase to October 2018 for studies comparing automated BP measurement devices to a standard mercury sphygmomanometer contemporaneously. Data were extracted by two reviewers. Mean BP differences between devices and mercury were calculated, where not reported and compared; meta-analyses were undertaken where possible. We included 13 studies reporting 14 devices. Mean systolic and diastolic BP differences from mercury ranged from −3.1 to + 6.1/−4.6 to +9.0 mmHg. Considerable heterogeneity existed between devices (I 2 : 80 to 90%). Devices with AF detection algorithms appeared no more accurate for BP measurement with AF than other devices. A previous review concluded that oscillometric devices are accurate for systolic but not diastolic BP measurement in AF. The present findings do not support that conclusion. Due to heterogeneity between devices, they should be evaluated on individual performance. We found no evidence that devices with AF detection measure BP more accurately in AF than other devices. More home or ambulatory automated BP monitors require validation in populations with AF.en_GB
dc.description.sponsorshipNational Institute for Health Research (NIHR)en_GB
dc.identifier.citationPublished online 10 January 2019en_GB
dc.identifier.doi10.1038/s41371-018-0153-z
dc.identifier.urihttp://hdl.handle.net/10871/37091
dc.language.isoenen_GB
dc.publisherSpringer Natureen_GB
dc.rights.embargoreasonUnder embargo until 10 July 2019 in compliance with publisher policyen_GB
dc.rights© Springer Nature Limited 2018en_GB
dc.titleAccuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysisen_GB
dc.typeArticleen_GB
dc.date.available2019-05-14T13:47:57Z
dc.identifier.issn0950-9240
dc.descriptionThis is the author accepted manuscript. The final version is available from Springer Nature via the DOI in this recorden_GB
dc.identifier.journalJournal of Human Hypertensionen_GB
dc.rights.urihttp://www.rioxx.net/licenses/all-rights-reserveden_GB
dcterms.dateAccepted2018-11-26
rioxxterms.versionAMen_GB
rioxxterms.licenseref.startdate2019-01-10
rioxxterms.typeJournal Article/Reviewen_GB
refterms.dateFCD2019-05-14T13:45:09Z
refterms.versionFCDAM
refterms.panelAen_GB


Files in this item

This item appears in the following Collection(s)

Show simple item record