Show simple item record

dc.contributor.authorAo, WK
dc.contributor.authorReynolds, P
dc.date.accessioned2019-11-21T11:39:06Z
dc.date.issued2019-11-12
dc.description.abstractThe electromagnetic coupling effect can generate electromagnetic damping to suppress disturbance, which can be utilised for vibration serviceability control in civil engineering structures. An electrodynamic actuator is used as a passive electromagnetic damper (EMD). The EMD is assumed to be attached between the ground and the structure ideally. The kinetic energy of the vibrating structure can be converted to electrical energy to activate the electromagnetic damping. To induce appropriate damping, the two terminals of the damper need to be closed and cascaded with a resonant shunt circuit as an electromagnetic shunt damper (EMSD). In this study, an RLC oscillating circuit is chosen. For determination of optimal circuit components and comparing against the tuned mass damper (TMD), existing H∞ design formulae are applied. This work extends this with a detailed development of an H2 robust optimisation technique. The dynamic properties of a footbridge structure are then selected and used to verify the EMSD optimal design numerically. The vibration suppression performance is analytically equivalent to the dynamic characteristic of the TMD and has feasible installation and better damping enhancement. To further evaluate the potential application of the EMSD, multi-vibration mode manipulation via connecting multiple RLC resonant shunt circuits is adopted. The multiple RLC shunt circuit connecting to EMD is an alternative to the single-mode control of a traditional TMD. Therefore, the EMSD can, in principle, effectively achieve suppression of single and multiple vibration modes.</jats:p>en_GB
dc.description.sponsorshipEngineering and Physical Sciences Research Council (EPSRC)en_GB
dc.identifier.citationPublished online November 12, 2019en_GB
dc.identifier.doi10.1115/1.4045455
dc.identifier.grantnumberEP/J004081/2en_GB
dc.identifier.urihttp://hdl.handle.net/10871/39670
dc.language.isoenen_GB
dc.publisherAmerican Society of Mechanical Engineersen_GB
dc.rightsCopyright © 2019 by ASMEen_GB
dc.titleAnalysis and numerical evaluation of H∞ and H2 optimal design schemes for an electromagnetic shunt damperen_GB
dc.typeArticleen_GB
dc.date.available2019-11-21T11:39:06Z
dc.identifier.issn1048-9002
dc.descriptionThis is the author accepted manuscript. The final version is available from American Society of Mechanical Engineers via the DOI in this record.en_GB
dc.identifier.journalJournal of Vibration and Acousticsen_GB
dc.rights.urihttp://www.rioxx.net/licenses/all-rights-reserveden_GB
dcterms.dateAccepted2019-11-07
exeter.funder::Engineering and Physical Sciences Research Council (EPSRC)en_GB
rioxxterms.versionAMen_GB
rioxxterms.typeJournal Article/Reviewen_GB
refterms.dateFCD2019-11-21T11:37:55Z
refterms.versionFCDAM
refterms.dateFOA2019-11-21T11:39:13Z
refterms.panelBen_GB


Files in this item

This item appears in the following Collection(s)

Show simple item record