dc.contributor.author | Toropov, N | |
dc.contributor.author | Osborne, E | |
dc.contributor.author | Joshi, LT | |
dc.contributor.author | Davidson, J | |
dc.contributor.author | Morgan, C | |
dc.contributor.author | Page, J | |
dc.contributor.author | Pepperell, J | |
dc.contributor.author | Vollmer, F | |
dc.date.accessioned | 2021-08-16T14:50:16Z | |
dc.date.issued | 2021-08-14 | |
dc.description.abstract | This review covers emerging biosensors for SARS-CoV-2 detection together with a review of the biochemical and clinical assays that are in use in hospitals and clinical laboratories. We discuss the gap in bridging the current practice of testing laboratories with nucleic acid amplification methods, and the robustness of assays the laboratories seek, and what emerging SARS-CoV-2 sensors have currently addressed in the literature. Together with the established nucleic acid and biochemical tests, we review emerging technology and antibody tests to determine the effectiveness of vaccines on individuals. | en_GB |
dc.identifier.citation | Published online 14 August 2021 | en_GB |
dc.identifier.doi | 10.1021/acssensors.1c00612 | |
dc.identifier.uri | http://hdl.handle.net/10871/126781 | |
dc.language.iso | en | en_GB |
dc.publisher | American Chemical Society (ACS) | en_GB |
dc.rights.embargoreason | Under embargo until 14 August 2022 in compliance with publisher policy | en_GB |
dc.rights | © 2021 American Chemical Society | en_GB |
dc.subject | coronavirus | en_GB |
dc.subject | SARS-CoV-2 | en_GB |
dc.subject | clinical tests | en_GB |
dc.subject | PCR | en_GB |
dc.subject | RNA | en_GB |
dc.subject | mutations | en_GB |
dc.subject | lateral flow devices | en_GB |
dc.subject | sensors | en_GB |
dc.subject | biosensors | en_GB |
dc.subject | electrical sensors | en_GB |
dc.subject | optical sensors | en_GB |
dc.subject | mechanical sensors | en_GB |
dc.title | SARS-CoV-2 Tests: Bridging the Gap between Laboratory Sensors and Clinical Applications | en_GB |
dc.type | Article | en_GB |
dc.date.available | 2021-08-16T14:50:16Z | |
dc.identifier.issn | 2379-3694 | |
exeter.article-number | acssensors.1c00612 | en_GB |
dc.description | This is the author accepted manuscript. The final version is available from the American Chemical Society via the DOI in this record | en_GB |
dc.identifier.journal | ACS Sensors | en_GB |
dc.rights.uri | http://www.rioxx.net/licenses/all-rights-reserved | en_GB |
dcterms.dateAccepted | 2021-07-28 | |
rioxxterms.version | AM | en_GB |
rioxxterms.licenseref.startdate | 2021-08-14 | |
rioxxterms.type | Journal Article/Review | en_GB |
refterms.dateFCD | 2021-08-16T12:38:32Z | |
refterms.versionFCD | AM | |
refterms.dateFOA | 2022-08-13T23:00:00Z | |
refterms.panel | B | en_GB |