Show simple item record

dc.contributor.authorVergari, C
dc.contributor.authorRibes, G
dc.contributor.authorAubert, B
dc.contributor.authorAdam, C
dc.contributor.authorMiladi, L
dc.contributor.authorIlharreborde, B
dc.contributor.authorAbelin-Genevois, K
dc.contributor.authorRouch, P
dc.contributor.authorSkalli, W
dc.date.accessioned2016-02-18T10:15:52Z
dc.date.issued2015-01-01
dc.description.abstractStudy design: Retrospective validation study. Objectives: To propose a method to evaluate, from a clinical standpoint, the ability of a finite-element model (FEM) of the trunk to simulate orthotic correction of spinal deformity and to apply it to validate a previously described FEM. Summary of background data: Several FEMs of the scoliotic spine have been described in the literature. These models can prove useful in understanding the mechanisms of scoliosis progression and in optimizing its treatment, but their validation has often been lacking or incomplete. Methods: Three-dimensional (3D) geometries of 10 patients before and during conservative treatment were reconstructed from biplanar radiographs. The effect of bracing was simulated by modeling displacements induced by the brace pads. Simulated clinical indices (Cobb angle, T1-T12 and T4-T12 kyphosis, L1-L5 lordosis, apical vertebral rotation, torsion, rib hump) and vertebral orientations and positions were compared to those measured in the patients' 3D geometries. Results: Errors in clinical indices were of the same order of magnitude as the uncertainties due to 3D reconstruction; for instance, Cobb angle was simulated with a root mean square error of 5.7°, and rib hump error was 5.6°. Vertebral orientation was simulated with a root mean square error of 4.8° and vertebral position with an error of 2.5 mm. Conclusions: The methodology proposed here allowed in-depth evaluation of subject-specific simulations, confirming that FEMs of the trunk have the potential to accurately simulate brace action. These promising results provide a basis for ongoing 3D model development, toward the design of more efficient orthoses.en_GB
dc.description.sponsorshipParisTech BiomecAM chair programen_GB
dc.description.sponsorshipProteoren_GB
dc.description.sponsorshipParisTechen_GB
dc.description.sponsorshipYves Cotrel Foundationsen_GB
dc.identifier.citationVol. 3, No. 1, pp. 4-11en_GB
dc.identifier.doi10.1016/j.jspd.2014.06.014
dc.identifier.urihttp://hdl.handle.net/10871/19926
dc.publisherElsevieren_GB
dc.relation.urlhttp://www.sciencedirect.com/science/article/pii/S2212134X14001208en_GB
dc.rights© 2015 Scoliosis Research Society. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en_GB
dc.titleEvaluation of a patient-specific finite-element model to simulate conservative treatment in adolescent idiopathic scoliosisen_GB
dc.typeArticleen_GB
dc.date.available2016-02-18T10:15:52Z
dc.identifier.issn2212-134X
dc.descriptionPublisheden_GB
dc.descriptionJournal Articleen_GB
dc.descriptionAuthor's accepted manuscript.en_GB
dc.identifier.journalSpine Deformityen_GB


Files in this item

This item appears in the following Collection(s)

Show simple item record