Show simple item record

dc.contributor.authorDubois, G
dc.contributor.authorKheireddine, W
dc.contributor.authorVergari, C
dc.contributor.authorBonneau, D
dc.contributor.authorThoreux, P
dc.contributor.authorRouch, P
dc.contributor.authorTanter, M
dc.contributor.authorGennisson, JL
dc.contributor.authorSkalli, W
dc.date.accessioned2016-02-18T13:50:05Z
dc.date.issued2015-06-27
dc.description.abstractDevelopment of shear wave elastography gave access to non-invasive muscle stiffness assessment in vivo. The aim of the present study was to define a measurement protocol to be used in clinical routine for quantifying the shear modulus of lower limb muscles. Four positions were defined to evaluate shear modulus in 10 healthy subjects: parallel to the fibers, in the anterior and posterior aspects of the lower limb, at rest and during passive stretching. Reliability was first evaluated on two muscles by three operators; these measurements were repeated six times. Then, measurement reliability was compared in 11 muscles by two operators; these measurements were repeated three times. Reproducibility of shear modulus was 0.48 kPa and repeatability was 0.41 kPa, with all muscles pooled. Position did not significantly influence reliability. Shear wave elastography appeared to be an appropriate and reliable tool to evaluate the shear modulus of lower limb muscles with the proposed protocol.en_GB
dc.description.sponsorshipParisTech BiomecAM chair program on subject-specific musculoskeletal modellingen_GB
dc.identifier.citationVol. 41, Iss. 9, pp. 2284 - 2291en_GB
dc.identifier.doi10.1016/j.ultrasmedbio.2015.04.020
dc.identifier.otherS0301-5629(15)00319-1
dc.identifier.urihttp://hdl.handle.net/10871/19940
dc.language.isoenen_GB
dc.publisherElsevieren_GB
dc.relation.urlhttp://www.ncbi.nlm.nih.gov/pubmed/26129731en_GB
dc.relation.urlhttp://www.sciencedirect.com/science/article/pii/S0301562915003191en_GB
dc.rights.embargoreasonPublisher's policy.en_GB
dc.rightsCopyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/en_GB
dc.subjectElastographyen_GB
dc.subjectLower limben_GB
dc.subjectMuscleen_GB
dc.subjectReliabilityen_GB
dc.subjectShear modulusen_GB
dc.titleReliable protocol for shear wave elastography of lower limb muscles at rest and during passive stretching.en_GB
dc.typeArticleen_GB
dc.identifier.issn0301-5629
exeter.place-of-publicationEngland
dc.descriptionPublisheden_GB
dc.descriptionJournal Articleen_GB
dc.descriptionResearch Support, Non-U.S. Gov'ten_GB
dc.identifier.eissn1879-291X
dc.identifier.journalUltrasound in Medicine and Biologyen_GB


Files in this item

This item appears in the following Collection(s)

Show simple item record