dc.description.abstractRaman spectroscopy (RS) is a powerful technique that permits the non-destructive chemical analysis of cells and tissues without the need for expensive and complex sample preparation. To date, samples have been routinely mounted onto calcium fluoride (CaF2) as this material possesses the desired mechanical and optical properties for analysis, but CaF2 is both expensive and brittle and this prevents the technique from being routinely adopted. Furthermore, Raman scattering is a weak phenomenon and CaF2 provides no means of increasing signal. For RS to be widely adopted, particularly in the clinical field, it is crucial that spectroscopists identify an alternative, low-cost substrate capable of providing high spectral signal to noise ratios with good spatial resolution. Results show that these desired properties are attainable when using mirrored stainless steel as a Raman substrate. When compared with CaF2, data show that stainless steel has a low background signal and provides an average signal increase of 1.43 times during tissue analysis and 1.64 times when analyzing cells. This result is attributed to a double-pass of the laser beam through the sample where the photons from the source laser and the forward scattered Raman signal are backreflected and retroreflected from the mirrored steel surface and focused towards collection optics. The spatial resolution on stainless steel is at least comparable to that on CaF2 and it is not compromised by the reflection of the laser. Steel is a fraction of the cost of CaF2 and the reflection and focusing of photons improve signal to noise ratios permitting more rapid mapping. The low cost of steel coupled with its Raman signal increasing properties and robust durability indicates that steel is an ideal substrate for biological and clinical RS as it possesses key advantages over routinely used CaF2. © 2016 The Authors. Journal of Raman Spectroscopy Published by John Wiley & Sons Ltd.en_GB
dc.description.sponsorshipInnovate UK – ‘SMART: Stratified Medicine through Advanced Raman Technologies’ UCL/UCLH Biomedical Research Centre (BRC)en_GB
dc.identifier.citationVol. 48, Iss. 1, pp. 119 - 125en_GB
dc.identifier.doi10.1002/jrs.4980
dc.identifier.otherJRS4980
dc.identifier.urihttp://hdl.handle.net/10871/26281
dc.language.isoenen_GB
dc.publisherWileyen_GB
dc.relation.urlhttps://www.ncbi.nlm.nih.gov/pubmed/28163358en_GB
dc.rights© 2016 The Authors. Journal of Raman Spectroscopy Published by John Wiley & Sons Ltd. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.en_GB
dc.subjectRaman spectroscopyen_GB
dc.subjectsignal improvementen_GB
dc.subjecttissueen_GB
dc.titleMirrored stainless steel substrate provides improved signal for Raman spectroscopy of tissue and cells.en_GB
dc.typeArticleen_GB
dc.date.available2017-03-07T09:24:59Z
dc.identifier.issn0377-0486
exeter.place-of-publicationEnglanden_GB
dc.descriptionPublisheden_GB
dc.descriptionJournal Articleen_GB
dc.descriptionThis is the final version of the article. Available from Wiley via the DOI in this record.en_GB
dc.identifier.eissn1097-4555
dc.identifier.journalJournal of Raman Spectroscopyen_GB


Files in this item

This item appears in the following Collection(s)

Show simple item record