Show simple item record

dc.contributor.authorLin, R
dc.contributor.authorClowsley, AH
dc.contributor.authorJayasinghe, ID
dc.contributor.authorBaddeley, D
dc.contributor.authorSoeller, C
dc.date.accessioned2018-01-11T13:37:37Z
dc.date.issued2017-05-10
dc.description.abstractModern sCMOS cameras are attractive for single molecule localization microscopy (SMLM) due to their high speed but suffer from pixel non-uniformities that can affect localization precision and accuracy. We present a simplified sCMOS non-uniform noise model that incorporates pixel specific read-noise, offset and sensitivity variation. Using this model we develop a new weighted least squared (WLS) fitting method designed to remove the effect of sCMOS pixel non-uniformities. Simulations with the sCMOS noise model, performed to test under which conditions sCMOS specific localization corrections are required, suggested that pixel specific offsets should always be removed. In many applications with thick biological samples photon fluxes are sufficiently high that corrections of read-noise and sensitivity correction may be neglected. When correction is required, e.g. during fast imaging in thin samples, our WLS fit procedure recovered the performance of an equivalent sensor with uniform pixel properties and the fit estimates also attained the Cramer-Rao lower bound. Experiments with sub-resolution beads and a DNA origami test sample confirmed the results of the simulations. The WLS localization procedure is fast to converge, compatible with 2D, 3D and multi-emitter localization and thus provides a computationally efficient sCMOS localization approach compatible with most SMLM modalities.en_GB
dc.description.sponsorshipHuman Frontier Science Program (RGP0027/2013) and EPSRC (EP/N008235/1).en_GB
dc.identifier.citationVol. 25 (10), pp. 11701 - 11716en_GB
dc.identifier.doi10.1364/OE.25.011701
dc.identifier.urihttp://hdl.handle.net/10871/30907
dc.language.isoenen_GB
dc.publisherOptical Society of Americaen_GB
dc.relation.urlhttps://www.ncbi.nlm.nih.gov/pubmed/28788730en_GB
dc.rightsOpen access. Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License: https://creativecommons.org/licenses/by/4.0/. Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI.en_GB
dc.titleAlgorithmic corrections for localization microscopy with sCMOS cameras - characterisation of a computationally efficient localization approachen_GB
dc.typeArticleen_GB
dc.date.available2018-01-11T13:37:37Z
exeter.place-of-publicationUnited Statesen_GB
dc.descriptionThis is the final version of the article. Available from OSA via the DOI in this record.en_GB
dc.identifier.journalOptics Expressen_GB


Files in this item

This item appears in the following Collection(s)

Show simple item record